For LED size 50, 100 and 170mm
For Face Plates Ultra Flat
For concrete pools with liner
Take the VISION Wall Conduit 1,5”, place the gasket and the polymer niche flange on top, screw it all together. Finish the pool construction and place the liner. Put the stainless steel mounting ring on the liner with a gasket in between.
Screw everything into the polymer niche flange for a watertight finish. Click the light into the Face Plate Ultra Flat and push it into the wall conduit.